Manuals and User Guides for Potterton Suprima 60L. We have 1 Potterton Suprima 60L manual available for free PDF download: Installation & Service. Potterton Suprima 60 HEG.C. No. 41 38 Pdf User Manuals. View online or download Potterton Suprima 60 HEG.C. No. 41 38 Installation & Service. We have 2 Potterton Suprima 60 HE manuals available for free PDF download: Installation & Service Instructions Manual, User’s Manual And Important Warranty .

Author: Shakazuru Talmaran
Country: Reunion
Language: English (Spanish)
Genre: Environment
Published (Last): 2 December 2005
Pages: 277
PDF File Size: 19.29 Mb
ePub File Size: 14.55 Mb
ISBN: 790-8-47684-497-8
Downloads: 47212
Price: Free* [*Free Regsitration Required]
Uploader: Brazilkree

Completely shutting off the power to the boiler sometimes allows troublesome PCBs to reset but, again, it made no difference. Potterton suprima 60 manual we find Suprima boilers where the membrane panel has been pressed so many times that the plastic membrane carrying the word “Reset” has broken away.

Potterton Suprima 60 HEG.C. No. 41 075 38 Manuals

Find great deals on eBay for potterton suprima 60 pcb and potterton potterton suprima 60 manual pcb. Wed Dec 13th I had my heating chap round who suspected a thermistor fault, I wasn’t sure about that as there were other symptoms.

Send us an potterton suprima 60 manual and a member of our team will have a look for you! Going upstairs to the airing cupboard we listened to the pump during the ignition attempt using a screwdriver between pump body and ear.

If the flame rectification current is not sensed by the circuit board the board will shut down the ignition sequence and go through the process again, three times in all. If the resistance was outside this range we should try replacing the thermistor, if within the range, and potterton suprima 60 manual checked potterton suprima 60 manual wiring connections between thermistor and PCB, we should suspect the PCB.

TOP Related  WEISHAUPT BURNER MANUAL EPUB DOWNLOAD

If you continue without changing your settings, we’ll assume that you are happy to receive all cookies on our website. Both organisations would also highlight Regulation 26 7 from the Gas Safety Installation and Use Regulations which potterton suprima 60 manual If the boiler is in lockout, the instructions tell you to press and hold the reset button for more than 10 seconds then count the flashes; 2 flashes indicate that the lockout was caused by ignition failure, 5 flashes indicate that lockout was caused by overheat In our case, none of the above fault light codes applied and we rang Potterton Technical for advice.

The later, more conventional leads translucent plastic round a metal coreare fine.

Potterton Suprima 60 Boiler Fault. In the manual that comes with the Siemens replacement PCB kit Potterton list a number of fault states: The boiler we saw was in a tight enclosed cupboard with no ventilation.

Continuous red indicates a PCB fault. Keep the instructions in a safe place and ensure that the Service Interval Record at the back is completed at each service visit.

Potterton suprima 60 manual are your nearest Pick Up Locations. However, when on it appears to go in 3 minute cycles, each on comprising of: All new parts come with manufacturers warranty. In we had the ‘lockout’ problem and had the new PCB upgrade kit fitted part no.

Changing the pump speed settings altered the hum but it still would not turn. Please complete the warranty registration document supplied with your boiler or register on-line at www.

The early leads were composed of a graphite core formed round glass fibre thread and covered with a red, rubberised insulation. Have a look at these links http: This potterton suprima 60 manual the range suitable for a wide range of property installations. Need help finding your Water Heater Spares Uk? I have an account. These are the Suprima ignition leads which give lockout problems.

TOP Related  PSM PARK 22ND EDITION DOWNLOAD

• View topic – Potterton-SuprimaHE-installation-manual

It potterton suprima 60 manual there might be a problem with the new PCB’s too! Swale Heating is proud to be trusted by overcustomers to keep them safe and warm, every day of every year. Potterton Suprima We aim to be the cheapest and easiest Potterton spares and parts supplier online, so if you find this product cheaper elsewhere please contact us pottertpn we will.

Powermax he installation servicing instructions ac wilgar. So far, this summer has proved to be somewhat of a heatwave, which inevitably will lead to calls of a hosepipe ban to be enforced to save water. The wording could have been better.

The red ignition lead serves a second purpose. Mrs Helen Taylor We were very pleased with our service from Swale heating. Save energy Energy saving tips. Suprima 40L potterton suprima 60 manual G. According to a note on the side of the PCB, continuous red can also indicate that the Pump Live is not wired directly from the boiler or that Live and Neutral are reversed polarity.

Potterton Potterton suprima 60 manual boiler shuts down after 15 minutes, then “dead” for hours with no lights before working again.

Potterton Suprima Gas Boiler Faults, Problems and Fault-finding

Please read our Legal Disclaimer. Manufacturer Aqualisa Mira Redring Triton. This guaranteed that the fault was the Enertech circuit board.